40PC Series
Fully signal conditioned pressure transducer
40PC150G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
150
Unit
psig
Zero pressure offset
Span4
0.46
3.93
0.50
4.0
0.54
4.07
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±2.5
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
40PC250G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
250
Unit
psig
Zero pressure offset
Span4
0.46
3.93
0.50
4.0
0.54
4.07
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±0.75
±1.0
±2.0
±0.75
±1.0
±2.0
±0.75
±1.0
±3.0
±3.0
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
6/8
November 2007 / 573
www.sensortechnics.com