26PC Series (psi)
Temp. compensated and calibrated pressure sensors
PRESSURE SENSOR CHARACTERISTICS
Vs = 10.0 ± 0.01 V, tamb = 20°C (unless otherwise noted)
Full-scale span2
Typ.
Listing
Order number
Operating pressure
Min.
14.7 mV
47 mV
97 mV
97 mV
95 mV
143 mV
Max.
18.7 mV
53 mV
26PCAFAxx
26PCBFAxx
26PCCFAxx
26PCDFAxx
26PCFFAxx
26PCGFAxx
26PC0070xxA
26PC0350xxA
26PC1000xxA
26PC2000xxA
26PC7000xxA
26PC17K0xxA
0 - 1 psi (69 mbar)
0 - 5 psi (345 mbar)
0 - 15 psi (1034 mbar)
0 - 30 psi (2068 mbar)
0 - 100 psi (6.9 bar)
0 - 250 psi (17.2 bar)
16.7 mV
50 mV
100 mV
103 mV
103 mV
105 mV
157 mV
100 mV
100 mV
150 mV
COMMON PERFORMANCE CHARACTERISTICS
Vs = 10.0 ± 0.01 V, tamb = 25°C (unless otherwise noted)
Characteristics
all 100 psi devices
Min.
-2.0
-1.5
Typ.
Max.
+2.0
+1.5
Unit
Zero pressure offset
all other devices
Temperature effects (0 - 50°C)4
Offset
mV
all 1 to 15 psi devices
all 30 psi devices
all other devices
±0.5
±0.75
±1.0
±1.0
±1.5
±2.0
±2.0
Span
all 1 psi devices
±1.0
all other devices
±0.75...±1.0
±0.25
±1.5
±0.5
±0.2
±0.7
Linearity (P2 > P1, BSL)3
all 1 to 15 psi devices
all 30 psi devices
all other devices
±0.1
±0.1
% span
Repeatability and hysteresis5
Long term stability7
Input impedance
±0.2
±0.5
7.5
5.5
1.5
11.5
3.0
kΩ
Output impedance
Response time6
2.5
1.0
ms
Specification notes:
1. The maximum specified pressure which may be applied to the sensor without causing a permanent change in the output characteristics.
2. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
3. Linearity (BSL), the deviation of measured output at constant temperature (25°C) from "Best Straight Line" determined by three
points, offset pressure, full-scale pressure and half full-scale pressure.
Vfull scale - Voffset
(full scale pressure)
V
–
x (½ full scale pressure) + Voffset
: 2 (Vfull scale) x 100 %
[
{
}]
½ full scale
where: V = measured value for each device
4. Error band of the offset voltage, span or bridge impedance in the specified temperature range, relative to the 25°C reading.
5. Repeatability, the deviation in output readings for successive application of any given input pressure (all other conditions
remaining constant. Hysteresis, the error defined by the deviation in output signal obtained when a specific pressure point is
approached first with increasing pressure, then with decreasing pressure or vice versa (all other conditions remaining constant).
6. Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure.
7. Long term stability of offset and span over a period over one year.
8. The sensors might be used on both ports, for media compatible with the components, specified under "Service" (page 1).
9. Other sealing materials are available on request. Minimum order quantities might be required.
10. Other pressure port styles, like barbed ones, luers, modular, M5, needle style or flow through connection, are
available on request. Minimum order quantities might be required.
2/4
January 2004 / 597
www.sensortechnics.com