160PC...-PCB Series
Fully signal conditioned low pressure transducer
163PC01D36-PCB
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, V
S
= 8.00 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Operating pressure
Zero pressure offset
Output voltage
Thermal effects (+5 to +45°C)
3
at -5"H
2
O
at +5"H
2
O
Offset
Span
Combined offset and span
Non-linearity (BSL)
2
Hysteresis and repeatability
Ratiometricity
Current consumption (no load)
Response time
Radiated, radio frequency electromagnetic field immunity (RFI),
EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz)
7 to 8 V and 8 to 9 V
9 to 12 V
Min.
-5
3.45
0.80
5.90
Typ.
3.50
1.00
6.00
Max.
+5
3.55
1.20
6.10
±1.0
±1.0
±1.0
±1.0
Unit
"H
2
O
V
%FSS
±0.25
±0.5
±2.0
20.0
1
10
mA
msec
V/m
164PC01D37-PCB
PERFORMANCE CHARACTERISTICS
Min.
0
0.95
5.90
Offset
Span
Combined offset and span
1.00
5.0
6.00
6.10
±1.0
±1.0
±1.0
±1.0
±0.25
7 to 8 V and 8 to 9 V
9 to 12 V
±0.5
±2.0
20.0
1
10
mA
msec
V/m
%FSS
(unless otherwise noted, V
S
= 8.00 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Operating pressure
Zero pressure offset
Span
4
Full scale output
Thermal effects (+5 to +45°C)
3
Typ.
Max.
10
1.05
Unit
"H
2
O
V
Non-linearity (BSL)
2
Hysteresis and repeatability
Ratiometricity
Current consumption (no load)
Response time
Radiated, radio frequency electromagnetic field immunity (RFI),
EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz)
June 2006 / 567
3/6
www.sensortechnics.com