144L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted VS = 8 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
Operating pressure2
144LP05D-PCB
144LP10D-PCB
144LP20D-PCB
144LP50D-PCB
0
0
0
0
5
10
20
50
mbar
144LU01D-PCB
144LU02D-PCB
144LU05D-PCB
144LU10D-PCB
144LU20D-PCB
0
0
0
0
0
1
2
5
"H2O
10
20
Zero pressure offset
Full scale output
Full scale span3
-0.05
4.9
0
5.0
5.0
±0.05
±0.02
±0.02
±0.01
0.05
5.1
V
Thermal effects (0 to 50°C)4
Offset 144LU01D-PCB
144LU02D-PCB
±0.15
±0.07
±0.07
±0.03
%FSO/°C
144LP05D-PCB
all other devices
Span
144LU01D-PCB
±0.05
±0.10
all other devices
±0.02
±0.04
%FSO
Non-linearity and hysteresis (BSL)5
Long term stability6
Response time (10 to 90%)
Position sensitivity
0.1
±0.2
200
0.5
µs
144LU01D-PCB
all other devices
0.5
%FSO/g
mA
0.1
Current consumption
4.2
Power supply rejection
Offset
Span
0.05
%FSO/V
0.03
Specification notes:
1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
2. The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when
vacuum is applied to port A relative to port B.
3. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
4. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
5. Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C.
6. Change in output after one year or 1 million pressure cycles.
2/4
Januar 2005 / 004
www.sensortechnics.com