110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
1...6 V output version (unless otherwise noted VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Proof
pressure2
Common mode
Characteristics
Min. Typ. Max.
Unit
pressure
Operating
pressure3
differential 112LP02D-PCB
0
0
0
0
0
2
5
10
25
50
200
200
200
300
300
300
300
300
600
600
devices
112LP05D-PCB
112LP10D-PCB
112LP25D-PCB
112LP50D-PCB
mbar
pressure/
vacuum
113LP01D-PCB
113LP02D-PCB
113LP05D-PCB
113LP10D-PCB
113LP25D-PCB
113LP50D-PCB
-1
-2
-5
-10
-25
-50
1
2
5
10
25
50
200
200
200
200
300
300
300
300
300
300
600
600
devices3
differential 112LU01D-PCB
0
0
0
0
0
1
2
5
10
20
30
80
160
240
240
360
360
360
devices
112LU02D-PCB
112LU05D-PCB
112LU10D-PCB
112LU20D-PCB
112LU30D-PCB
120
120
240
240
240
"H2O
pressure/
vacuum
113LU01D-PCB
113LU02D-PCB
113LU05D-PCB
113LU10D-PCB
113LU20D-PCB
113LU30D-PCB
-1
-2
-5
-10
-20
-30
1
2
5
10
20
30
80
160
240
240
360
360
360
120
120
240
240
240
devices3
Zero pressure offset4
Full scale span5
112L...-PCB 0.95
1.0
3.5
1.05
3.6
113L...-PCB
3.4
112L...-PCB
113L...-PCB
4.9
2.4
5.0
2.5
5.1
2.6
V
Full scale output
6.0
1.0
Output at lowest specified pressure
113L...-PCB
Thermal effects
(0 to 50°C)6
Offset
113LP01D-PCB
11...LP02D-PCB
11...LU01D-PCB
all other devices
±0.08 ±0.20
±0.04 ±0.10
±0.04 ±0.10
±0.02 ±0.05
%FSO/°C
Span
113LP01D-PCB
11...LP02D-PCB
11...LU01D-PCB
all other devices
±0.08 ±0.20
±0.04 ±0.10
±0.04 ±0.10
±0.02 ±0.04
Non-linearity and hysteresis (BSL)7
Long term stability8
±0.1 ±0.25
%FSO
ms
±0.5
1
Response time (10 to 90 %)
Position sensitivity
all 1 and 2 mbar devices
all other devices
0.5
0.1
%FSO/g
mA
Current consumption
4.2
Power supply
rejection
Offset
Span
0.05
0.05
%FSO/V
2/6
January 2007 / 006