Datasheet SHT1x
Sensor Performance
Relative Humidity123
Temperature45
Parameter
Parameter
Condition
min
typ max Units
Condition
min
typ max Units
0.4 0.05 0.05 %RH
0.04 0.01 0.01 °C
Resolution 1
Resolution 1
8
12
4.5
12
bit
12
14
0.5
14
bit
Accuracy 2
SHT10
Accuracy 2
SHT10
typical
%RH
typical
°C
maximal
typical
see Figure 2
maximal
typical
see Figure 3
Accuracy 2
SHT11
3.0
see Figure 2
2.0
Accuracy 2
SHT11
0.4
see Figure 3
0.3
%RH
%RH
°C
°C
°C
maximal
typical
maximal
typical
Accuracy 2
SHT15
Accuracy 2
SHT15
maximal
see Figure 2
0.1
maximal
see Figure 3
Repeatability
Hysteresis
%RH
%RH
%RH
s
Repeatability
0.1
-40
-40
5
123.8 °C
254.9 °F
1
<<1
Operating Range
Non-linearity
Response time 3
linearized
Response Time 6
Long term drift
30
s
8
(63%)
(63%)
< 0.04
°C/yr
Operating Range
Long term drift 4 normal
0
100 %RH
%RH/yr
< 0.5
± 10
± 8
± 3.0
± 2.5
SHT10
± 2.0
± 1.5
± 1.0
± 0.5
± 0.0
± 6
SHT11
SHT10
± 4
± 2
± 0
SHT11
SHT15
SHT15
0
10 20 30 40 50 60 70 80 90 100
-40
-20
0
20
40
60
80
100
Temperature (°C)
Relative Humidity (%RH)
Figure 3: Maximal T-tolerance per sensor type.
Figure 2: Maximal RH-tolerance at 25°C per sensor type.
Packaging Information
Electrical and General Items
Sensor Type
SHT10
Packaging
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Quantity Order Number
Parameter
Condition min
2.4
typ max Units
2000
100
1-100218-04
1-100051-04
1-100098-04
1-100524-04
1-100085-04
1-100093-04
Source Voltage
3.3
2
5.5
5
V
sleep
µW
mW
µW
Power
Consumption 5
SHT11
SHT15
400
measuring
average
3
2000
100
90
Communication digital 2-wire interface, see Communication
400
Storage
10 – 50°C (0 – 125°C peak), 20 – 60%RH
This datasheet is subject to change and may be
amended without prior notice.
1
4
The default measurement resolution of is 14bit for temperature and 12bit for
humidity. It can be reduced to 12/8bit by command to status register.
Value may be higher in environments with high contents of volatile organic
compounds. See Section 1.3 of Users Guide.
2
3
5
Accuracies are tested at Outgoing Quality Control at 25°C (77°F) and 3.3V.
Values exclude hysteresis and are applicable to non-condensing environments
only.
Values for VDD=3.3V at 25°C, average value at one 12bit measurement
per second.
6
Response time depends on heat capacity of and thermal resistance to
sensor substrate.
Time for reaching 63% of a step function, valid at 25°C and 1 m/s airflow.
www.sensirion.com
Version 4.3 – May 2010
2/11