SS695
Linear Hall Effect Sensor
Electrical Characteristics
Operation parameters TA =25°C,VCC =5.0V
Parameter
Symbol Test Conditions
Min
Typ
Max
Units
Operating Voltage
Supply Current
VCC
ICC
Operating
Average
4.5
5
10.5
8.0
V
mA
mA
uS
5
Output Current
IOUT
Tack
Vo
1.0
3.0
1.5
3
Response Time
Quiescent Output Voltage
Sensitivity
B = 0G
2.5
3.3
0.2
4.8
V
△Vout
TA= 25°C
B = -700G
B = 700G
3.6
mV/G
V
Min Output Voltage
Max Output Voltage
V
Magnetic Field Characteristics
Parameter
Test Conditions
Min
3.0
Typ
3.3
Max
Units
Sensitivity
TA= 25°C
3.6
mV/G
G
Range of magnetic field strength
Linearity
±650 ±700
﹣1.0
%
Operating Temperature
Zero drift
-40
+150
0.10
°C
﹣0.10
%/°C
%/°C
%/°C
TA ≥ 25°C
﹣0.15
0.05
Sensitivity temperature drift
TA< 25°C
﹣0.04
0.185
Installation Caution:
1. Should be installed by minimizing the mechanical stress on the Hall circuit;
2. On the conditions of ensuring the quality of the welding, the welding temperature and time should
be reduced as far as possible.
3
V3.10 Nov 1, 2013