SS3313
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Glossary of Terms
−
−
−
−
MilliTesla (mT), Gauss Units of magnetic flux density: 1mT = 10 Gauss
RoHS
ESD
Restriction of Hazardous Substances
Electro-Static Discharge
Operating Point (BOP) Magnetic flux density applied on the branded side of the package which turns the
output driver ON (VOUT = VDSon
)
−
Release Point (BRP)
Magnetic flux density applied on the branded side of the package which turns the
output driver OFF (VOUT = high)
Pin Definitions and Descriptions
SOT Pin № SIP Pin №
Name
VDD
Type
Supply
Output
Ground
Function
Supply Voltage pin
Open Drain Output pin
Ground pin
1
2
3
1
3
2
OUT
GND
Absolute Maximum Ratings
Parameter
Supply Voltage(operating)
Supply Current
Symbol
VDD
IDD
Value
Units
V
28
5
mA
V
Output Voltage
VOUT
IOUT
TA
28
Output Curent
10
mA
°C
Operating Temperature Range
Storage Temperature Rang
ESD Sensitivity
-40 to 150
-50 to 165
4000
TS
°C
-
V
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum rated conditions for ex-
tended periods may affect device reliability.
2