SS248
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Operating Parameters: TA = 25°C, VDD=2.75VDC
.
PARAMETER
Operating Point
Release Point
Hysteresis
Symbol
Bop
Min
Type
+/-35
+/-21
14
Max
Units
Gs
-
+/-5
-
+/-60
Brp
-
-
Gs
Bhys
Gs
ESD Protection
Human Body Model (HBM) tests according to: Mil. Std. 883F method 3015.7
Limit Values
Parameter
Symbol
Unit
Notes
Min
Max
ESD Voltage
VESD
kV
±4
Performance Characteristics
5
V3.10 Nov 1, 2013