SS159
Unipolar Hall Switch-Low Sensitivity
Glossary of Terms
MilliTesla (mT), Gauss
RoHS
Units of magnetic flux density: 1mT = 10 Gauss
Restriction of Hazardous Substances
Operating Point (BOP
)
Magnetic flux density applied on the branded side of the package which turns the output
driver ON (VOUT = VDSon
)
Release Point (BRP
)
Magnetic flux density applied on the branded side of the package which turns the output
driver OFF (VOUT = high)
Pin Definitions and Descriptions
SOT Pin № SIP Pin №
Name
Type
Function
1
2
3
1
3
2
VDD
OUT
GND
Supply
Output
Ground
Supply Voltage pin
Open Drain Output pin
Ground pin
Table 1: Pin definitions and descriptions
Absolute Maximum Ratings
Parameter
Symbol
VDD
IDD
Value
Units
V
Supply Voltage
Supply Current
Output Voltage
Output Current
28
50
28
50
mA
V
VOUT
IOUT
TS
mA
°C
Storage Temperature Range
-65 to 170
Table 2: Absolute maximum ratings
Operating Temperature Range Symbol
Value
Units
Temperature Suffix “E”
Temperature Suffix “K”
Temperature Suffix “L”
TA
TA
TA
-40 to 85
-40 to 125
-40 to 150
°C
°C
°C
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
2