SS1331
Unipolar Hall Switch-Low Sensitivity
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 3.5V to 24V (unless otherwise specified)
Typ
Parameter
Symbol
VDD
Test Conditions
Operating
Min
3.5
Max
24
Units
V
Supply Voltage
1.5
2.5
0.4
IDD
Supply Current
B < BRP
5
mA
V
VDSon
IOFF
IOUT = 20mA, B >
Output Saturation Voltage
Output Leakage Current
Output Rise Time
Output Fall Time
0.5
10
BOP
B <
VOUT = 24V
BRP
0.01
0.25
0.25
µA
µs
t
r
RL = 1kΩ, CL = 20pF
RL = 1kΩ, CL = 20pF
t
f
µs
Magnetic Specifications
DC Operating Parameters VDD = 3.5V to 24V (unless otherwise specified)
Package
Parameter
Symbol
BOP
Test Conditions
Min
45
Ta=25°C,Vdd=12V DC 10
Typ
Max
Units
G
Operating Point
Release Point
Hysteresis
80
110
95
UA
BRP
50
G
BHYST
BOP
30
G
Operating Point
Release Point
Hysteresis
-110
Ta=25°C,Vdd=12V DC -95
-80
-50
30
-45
-10
G
SO
BRP
G
BHYST
G
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40°C to 150°C, VDD = 3.5V to 24V (unless otherwise specified)
Test Conditions (UA) Test Conditions (SO)
OUT
High
Low
B < BRP
B > BOP
B > BRP
B < BOP
The SOT-23 device is reversed from the UA package. The SOT-23 output transistor will be turned on(drops low) in the presence of a
sufficiently strong North pole magnetic field applied to the marked face.
4
V3.10 Nov 1, 2013