SIOY2L1V2
Current Sensors
Features
Hall effect measuring principle
Galvanic isolation between primary and
secondary circuit
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 *IPN)
Insulated plastic case recognized according
to UL 94-V0
IPN = 50…600A VOUT = ± 4 V
Advantages
Industrial applications
Easy installation
AC variable speed drives
Excellent accuracy
No insertion losses
Excellent performance and price
Only one design for wide current ratings
range
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding applications
Static converters for DC motor drives
Switched-Mode Power Supplies (SMPS)
High immunity against external
interference
TYPES OF PRODUCTS
Primary nominal current
Primary current measuring range
Type
r. m. s IPN (A)
IP (A)
±150
±225
±300
±450
±600
±900
±900
±900
±900
SIOY2L150V2
SIOY2 L175V2
SIOY2 L1100V2
SIOY2 L1150V2
SIOY2 L1200V2
SIOY2 L1300V2
SIOY2 L1400V2
SIOY2 L1500V2
SIOY2 L1600V2
50
75
100
150
200
300
400
500
600
General Description
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit and the secondary circuit.
1
V2.00 May 1, 2012