Fuseholders
Shock-Safe Fuseholder, 5 x 20 mm, Slot, horizontal
FAB
250 VAC · 2.5 W / 10 A (VDE)12 A (UL)
Description
Standards
- Kicked or straight PCB-terminals
- Horizontal style
- IEC 60127-6
- UL 512
- CSA C22.2 no. 39
References
Weblinks
Approvals
- VDE License Number: 133921
- UL File Number: E39328
Technical Data
Shocksafe Category
Fuse-Link
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
PC2
5 x 20 mm
PCB
Solder THT
250 VAC
10 A (VDE), 12 A (UL)
2.5 W / 10 A @ Ta 23 °C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Degree of Protection
IP 40
Protection Class
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, UL 94V-0
Material: Cap
Thermoplastic, UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight (Socket/Cap)
5 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Voltage, Current, Approvals
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Wave
235 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
< 5 mΩ at 20 mV
> 3 kV between L-N
(50 Hz; 1 min)
> 4 kV between L-N
> 10 MΩ between L-N
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
1 - 3 acc. to IEC 60664-1
Abmessungen
31.5 mm
31.5
12
±0.2
6
1.3
+0.1
0
10.06
+0.1
0
1.8
5 5
10
±0.1
5
16.25 10
±0.3
1.1
Variant 0031.3551 and 0031.3558
Drilling diagram
Fuses