3507
AND
3508
RATIOMETRIC,
LINEAR HALL-EFFECT SENSORS
FOR HIGH-TEMP. OPERATION
MAGNETIC CHARACTERISTICS
over operating temperature range, at V
CC
= 5 V, I
O
= 1 mA
(unless otherwise noted).
Part Numbers
A3507LUA
Characteristic
*
˚Operating Temp. Range, T
A
˚Sensitivity at T
A
= 25°C
over Oper. Temp. Range
˚∆Sens
(∆T)
at T
A
= Max.
at T
A
= Min.
˚∆V
OQ(∆T)
˚Ratiometry,
∆V
OQ(∆V)
˚Ratiometry,
∆Sens
(∆V)
˚Positive Linearity, Lin+
˚Negative Linearity, Lin—
˚Symmetry
Min.
-40
2.0
1.7
-5.0
-8.8
—
—
—
—
—
—
Typ.
—
2.5
2.5
2.5
-1.3
—
100
100
100
100
100
Max.
+150
3.0
3.3
10
6.2
±35
—
—
—
—
—
Min.
-40
2.0
1.7
-6.3
-8.8
—
—
—
—
—
—
A3507EUA
Typ.
—
2.5
2.5
1.2
-1.3
—
100
100
100
100
100
Max.
+85
3.0
3.3
8.7
6.2
±35
—
—
—
—
—
Min.
-20
2.0
1.7
-10
-10
—
—
—
—
—
—
A3508SUA
Typ.
—
2.5
2.5
—
—
—
100
100
100
100
100
Max.
+85
3.0
3.3
10
10
±50
—
—
—
—
—
Units
°C
mV/G
mV/G
%
%
G
%
%
%
%
%
Magnetic flux density is measured at most sensitive area of device located 0.018" (0.46 mm) below the branded face of the “UA”
package.
* See Characteristics Definitions for test conditions.
† The nominal sensitivity temperature stability is designed to compensate for the temperature coefficient of samarium-cobalt
magnets (-0.02%/°C).
‡ This calculation (formula 1, next page) yields the device’s equivalent accuracy, over the operating temperature range, in gauss.
www.allegromicro.com