3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
TYPICAL OPERATING CHARACTERISTICS (cont.)
SENSOR LOCATIONS
(±0.005” [0.13 mm] die placement)
CHANGE IN OPERATE POINT
Suffix “LT”
ACTIVE AREA DEPTH
20
0.0305"
0.089"
0.775 mm
2.26 mm
NOM
15
0.043"
1.09 mm
T
= +25°C
A
A
10
1
2
3
5.0
Dwg. MH-008-2D
0
Suffix “U”
ACTIVE AREA DEPTH
0.0165"
0.42 mm
NOM
0.091"
2.31 mm
-5.0
0
5
10
15
20
25
SUPPLY VOLTAGE IN VOLTS
0.070"
Dwg. GH-042-1
1.78 mm
OPERATION
A
The output of these devices (pin 3) switches low when the magnetic field
at the Hall sensor exceeds the operate point threshold (BOP). At this point, the
output voltage is VOUT(SAT). When the magnetic field is reduced to below the
release point threshold (BRP), the device output goes high. The difference in
the magnetic operate and release points is called the hysteresis (Bhys) of the
device. This built-in hysteresis allows clean switching of the output even in
the presence of external mechanical vibration and electrical noise.
BRANDED
SURFACE
1
2
3
Dwg. MH-002-2C
Suffix “UA”
ACTIVE AREA DEPTH
0.0195"
0.50 mm
NOM
0.082"
2.07 mm
0.055"
1.39 mm
A
BRANDED
SURFACE
1
2
3
Dwg. MH-011-10A
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000