Storage, characteristic inspection, and handling precautions  
Inappropriate storage, characteristic inspection, or  
5. Soldering temperature  
handling may impair the reliability of the device. To ensure  
high reliability, observe the following precautions:  
If soldering is necessary, take care to keep the applica-  
tion of heat as brief as possible, and within the following  
limits:  
1. Storage precautions  
260±5ºC for 10 s max  
It is recommended to store the device at room temper-  
350ºC for 3 s max (soldering iron)  
ature (between 5 and 35°C) and relative humidity at 40 to  
75%. Avoid storing the device in a place where the  
temperature or humidity is high or changes greatly.  
6. Heatsink  
Store the device in a clean place that is not exposed to  
A large contact area between the device and the  
heatsink for effective heat radiation is required. To ensure  
a large contact area, minimize mounting holes and select a  
heatsink with a sufficiently smooth surface and that is free  
from burring or metal debris.  
direct sunlight, and is free from corrosive or harmful  
gases.  
If the device is stored for a long time, check the solder-  
ability and lead condition before using the device.  
2. Precautions on characteristic inspections  
7. Handling precautions to protect power  
MOS FET from static damage  
When carrying out characteristic inspections on re-  
ceiving products or other occasions, take care to avoid  
applying a surge voltage from the measuring equipment  
and check the terminals of the measuring equipment for a  
short circuit or wiring errors. Measure the device within the  
range of its rated values.  
When handling the device, physical grounding is neces-  
sary. Wear a wrist strap with a 1 Mresistor close to the  
body in the wrist strap to prevent electric shock.  
Use a conductive table mat or floor mat at the device  
handling workbench and to ensure grounding.  
When using a curve tracer or other measuring equip-  
ment, ground the equipment as well.  
3. Silicone Grease  
When soldering, ground the bit of the soldering iron and  
When attaching heatsink, apply a small amount of  
silicone evenly to the back of the device and both sides of  
the insulator to reduce the thermal resistance between the  
device and heatsink.  
the dip tank to prevent a leakage voltage from damaging  
the device.  
Store the device in the shipping container or a conduc-  
tive container or use aluminum foil to protect the device  
from static electricity.  
Recommended silicone grease  
G746  
SHINETSU SILICONE CO., LTD.  
YG6260 TOSHIBA SILICONE CO., LTD.  
8. Load on Leads  
SC102 DOW CORNING TORAY SILICONE CO., LTD.  
When excessive load is exerted on leads, internal  
connections may be break. Load exerted in each of the  
following directions should be limited to below 1 kg for  
TO-220F and 2.5 kg for TO-3PF.  
Please select a silicone grease carefully since the oil in  
some grease can penetrate the product, which will  
result in an extremely short product life.  
4. Screw tightening torque  
If screws are not tightened with sufficient torque, this  
can increase the thermal resistance and reduce the  
radiation effect. Tightening screws with too great a torque  
damage the screw thread, deform the heatsink, or twist the  
device frame until it is damaged. There, tighten screws with  
a torque as shown below (Table 1).  
Table 1: Screw Tightening Torque  
Directions in which load is exerted on leads  
Package  
TO-220F  
TO-3PF  
Tightening Torque  
9. Lead Forming  
0.490 to 0.686 N•m (5 to 7 kgf•cm)  
0.686 to 0.822 N•m (7 to 9 kgf•cm)  
We make several types of lead forming available, please  
consult with our personnel when necessary.  
2