SA9904B  
ELECTRICAL CHARACTERISTICS  
(VDD - VSS = 5V ± 10%, over the temperature range -40°C to +85°C, unless otherwise specified. Refer to Figure 2 “Test circuit for  
electrical characteristics”.)  
Parameter  
General  
Symbol  
Min  
Typ  
Max  
Unit  
Condition  
Supply Voltage:  
Positive  
VDD  
VSS  
IDD  
2.25  
2.5  
-2.5  
9.5  
2.75  
-2.25  
11  
V
V
With respect to AGND  
With respect to AGND  
Supply Voltage:  
Negative  
-2.75  
Supply Current:  
Positive  
mA  
mA  
Supply Current:  
Negative  
ISS  
-9.5  
-11  
Analog Inputs  
Current Sensor Inputs  
(Differential)  
IRIIP1, IRIIP2, IRIIP3  
IRIIN1, IRIIN2, IRIIN3  
,
Input Current Range  
Offset Voltage  
-25  
-4  
25  
4
µA  
Peak value  
VOIIP1, VOIIP2, VOIIP3  
VOIIN1, VOIIN2, VOIIN3  
,
With R = 4.7kconnected  
to AGND  
mV  
Voltage Sensor Inputs  
(Asymmetrical)  
Input Current Range  
IRIVP1, IRIVP2, IRIVP3  
-25  
-4  
25  
4
μA  
Peak value  
With R = 4.7kconnected  
to AGND  
Offset Voltage  
VOIVP1, VOIVP2, VOIVP3  
mV  
Digital Inputs  
SCK, CS, DI  
Input High Voltage  
Input Low Voltage  
VIH  
VIL  
VDD-1  
V
V
VSS+1  
800  
SCK  
Maximum clock frequency  
Minimum clock low time  
Minimum clock high time  
fSCK  
tLO  
tHI  
kHz  
μs  
μs  
0.6  
0.6  
Digital Outputs  
F50, DO  
Output High Voltage  
Output Low Voltage  
VOH  
VOL  
VDD-1  
V
V
ISOURCE = 5mA  
ISINK = 5mA  
VSS+1  
ATTENTION:  
Electrostatic  
sensitive device.  
Requires special  
handling.  
During manufacturing, testing and shipment we take great care to protect our products against potential external  
environmental damage such as Electrostatic Discharge (ESD). Although our products have ESD protection circuitry,  
permanent damage may occur on products subjected to high-energy electrostatic discharges accumulated on the  
human body and/or test equipment that can discharge without detection. Therefore, proper ESD precautions are  
recommended to avoid performance degradation or loss of functionality during product handling.  
SPEC-0447 (REV. 7)  
29-09-2017  