SA9605A  
PIN DESCRIPTION  
Designation  
Description  
Pin  
16  
6
GND  
VDD  
Ground  
Positive Supply Voltage  
Negative Suply Voltage  
14  
VSS  
17  
20  
3
IVN1  
IVN2  
IVN3  
IIN1  
Analog input for Voltage : Phase 1  
Analog input for Voltage : Phase 2  
Analog input for Voltage : Phase 3  
Inputs for Current sensor : Phase 1  
19  
18  
2
IIP1  
IIN2  
Inputs for Current sensor : Phase 2  
Inputs for Current sensor : Phase 3  
1
IIP2  
5
IIN3  
4
IIP3  
10  
11  
7
OSC1  
OSC2  
FOUT1  
FOUT2  
DIR  
Connections for crystal or ceramic resonator  
(OSC1 = Input ; OSC2 = Output)  
Pulse rate outputs  
8
9
Direction indicator  
12  
13  
15  
PGM0  
PGM1  
VREF  
FOUT2 Frequency select pins  
Connection for current setting resistor  
FUNCTIONAL DESCRIPTION  
The SAMES SA9605A is a CMOS mixed signal Analog/Digital integrated circuit, which  
performs three phase power/energy calculations over a range of 1000:1, to an overall  
accuracy of better than Class 1.  
The SA9605A in both DIP-20 and SOIC-20 package options is functionally similar to the  
SA9105E and SA9105F with the advantage of no external loop capacitors.  
The integrated circuit includes all the required functions for 3-phase power and energy  
measurement such as oversampling A/D converters for the voltage and current sense  
inputs, power calculation and energy integration. Internal offsets are eliminated through  
the use of cancellation procedures.  
The SA9605A generates pulses, the frequency of which is proportional to the power  
consumption. Twofrequencyoutputs(FOUT1andFOUT2)areavailable. Thepulserate  
follows the instantaneous power measured.  
4/14  
sames