SA9605A  
The frequencies shown in the above table were chosen to allow a 4 - 3 - 2 scaling ratio  
for rated conditions. This facility provides ease of interface with applications which use  
the same post divider with mechanical counter or unchanged microcontroller software  
for different current rated kWh meters.  
For example, a meter manufacturer may wish to build meters for 3 system configurations  
with rated current loading of 80ARMS, 60ARMS and 40ARMS. The rated line voltage is  
230VRMS  
.
FOUT1 Frequency  
Consider the case where FOUT1 is the output of the energy counting block. For each  
ofthethreeratedconditions, theinputcurrentsensingresistorsarechosentoensurethat  
16µARMS flows into the current sensing pins.  
Case 1 IL = 80ARMS  
80 230  
*
3
3
3
*
*
*
1 pulse on FOUT1 =  
Case 2 IL = 60ARMS  
1 pulse on FOUT1 =  
Case 3 IL = 40ARMS  
1 pulse on FOUT1 =  
= 47.6Ws  
= 35.7Ws  
= 23.8Ws  
1160  
60 230  
*
1160  
40 230  
*
1160  
The amount of energy represented by one pulse for each of the three cases is different.  
In addition to changing the current sensing resistor network, the energy counting block  
must also be altered.  
FOUT2 Frequency  
Now consider the advantage of the user selectable frequency available on FOUT2.  
Again the input current sensing resistors must be chosen to ensure that 16µARMS flows  
into the current sensing pins.  
Case 1 IL = 80ARMS  
,
PGM1 = 0 PGM0 = 0  
80 230  
3
*
*
1 pulse on FOUT2 =  
= 10.8kWs  
5.11  
Case 2 IL = 60ARMS  
,
PGM1 = 0 PGM0 = 1  
60 230  
3
*
*
1 pulse on FOUT2 =  
= 10.8kWs  
3.83  
Case 3 IL = 40ARMS,  
1 pulse on FOUT2 =  
sames  
PGM1 = 1 PGM0 = 0  
40 230  
3
*
*
= 10.8kWs  
2.55  
8/14