SA8806A
ABSOLUTE MAXIMUM RATINGS*
Parameter
Symbol
Min
-0.3
-100
-40
Max
6.0
Unit
V
Supply Voltage
VDD -VSS
IPIN
Current on any pin
Storage Temperature
Operating Temperature
+100
+125
+85
mA
°C
TSTG
TO
-25
°C
* Stressesabovethoselistedunder“AbsoluteMaximumRatings”maycausepermanent
damage to the device. This is a stress rating only. Functional operation of the device
at these or any other condition above those indicated in the operational sections of this
specification, is not implied. Exposure to Absolute Maximum Ratings for extended
periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(Over the temperature range -10°C to +70°C#, VDD = 5V, VSS = 0V unless otherwise
specified.)
Parameter
Symbol Min
Typ
Max Unit Condition
5.5
Supply Voltage
Supply Current
LCD ON Voltages
VDD-VSS
IDD
4.5
5.0
V
100 µA
VON
VDD & VSS
V
V
LCD OFF Voltages
VOFF
1/3VDD & 2/3 VDD
#
Extended Operating Temperature Range available on request.
3/10