SA8702
Operating Conditions:
All voltages measured with respect to VSS.
Inputs must never be left open.
DC Parameters
Symbol Min.
Nom. Max. Unit Conditions
Supply Voltage
VDD
VIL
4,75
-
5,00 5,25
V
V
-
* Input Low Voltage
-
1,0
VDD = 5V
* Input High Voltage
** Output Low Voltage
VIH
4,0
-
-
-
-
V
V
VDD = 5V
VDD = 5V
VOL
0,5
Iol
= 0,5mA
** Output High Voltage
VOH
4,5
-
-
V
VDD = 5V
Ioh
= 0,5mA
Operating Frequency
-
2,048 2,273 MHz 4,75 ≤ VDD
≤ 5,25
Operating Temp. range
-10
25
70
°C
-
* All inputs are C-MOS level compatible. Pins 6 and 7 have internal pull-up
devices.
** All outputs are push-pull except pin 1 which is open drain.
AC Parameters
Symbol
Min.
Nom. Max. Unit
Conditions
XSYNC setup before
BCLK goes low
Ts
60
-
-
ns
4,75 ≤ VDD
≤ 5,25
Output propagation
delay from active clock
edge
Tpd
Th
-
-
150
ns
4,75 ≤ Vdd
≤ 5,25
XSYNC hold time from
BCLK
50
-
-
ns
4,75 ≤ VDD
≤ 5,25
sa mes
3