SA7120A
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
MIN
MAX
UNIT
NOTE
Supply Voltage
VDD
-0.3
9.4
V
1,2,3,4,5
ESD protection C= 100pF R = 1.5Kohm ,
Human body model. MIL-STD-883C method
3015
Vpesd
-
TBD
V
3,8
Peak voltage across COIL1 or COIL2 to VSS
Peak current through COIL 1,2
Storage temperature
VCOIL1,2 - VSS
ICOIL1,2
-10
-30
-55
+10
+30
V
mA
oC
3,6
3,7
3
Tst
+125
Note 1: Duration not to exceed 10 seconds, and no logic switching.
Note 2:
Note 3:
Referenced to Vss
Stresses above those listed under “ absolute maximum ratings” may cause permanent damage to the device.
This is a stress rating only and functional operation of the device at these or any other conditions above those
indicated in the operating conditions section of this specification is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect the device reliability.
Note 4: VDD level when absolute maximum current goes through coil inputs.
Note 5: VDD level when absolute maximum voltage is across coil inputs.
Note 6: Maximum peak voltage at COIL1 or COIL2 of incoming RF signal with VSS as reference. Clamping by front end
protection circuitry.
Note 7: Maximum allowed peak current of incoming RF signal.
Note 8: TBD - To be determined.
HANDLING PROCEDURES
Although the device has built-in ESD protection, adherence to anti-static procedures for CMOS devices is required.
ELECTRICAL CHARACTERISTICS
DC Operating Conditions
Parameter
Symbol
Min
Typ
Max
Unit
Condition
µA
Dynamic current
IDD
3
6
VDD = 3V
VDD = 3V, clock stopped, COIL1 &
COIL2 shorted to VSS
Static current
IDDS
1
2
µA
V
Voltage when power-on reset
comes out of reset
VPOR
VPORH
1.2
1.6
During power-up VDD – VSS rising
Between coming out of reset and
going back into reset
Histereses on power-on rest
200
-
-
-
600
mV
Data retention
TDR
VDD
Top
10
2
-
years programmed
At specified current at COIL1 or
COIL2,
Supply voltage
5.5 1)
+70
V
Operating temperature
-40
oC
Note: 1) maximum voltage is defined when forcing 10 mA on the coil inputs.
4/10