SA4120A  
ELECTRICAL CHARACTERISTICS  
(VDD - VSS = 5V ± 10%, over the temperature range -40°C to +85°C, unless otherwise specified. Refer to Figure 2 “Test circuit for  
electrical characteristics”.)  
Parameter  
General  
Symbol  
Min  
Typ  
Max  
Unit  
Condition  
Supply Voltage:  
Positive  
VDD  
VSS  
IDD  
2.25  
2.5  
-2.5  
3.5  
2.75  
-2.25  
4.5  
V
V
With respect to AGND  
With respect to AGND  
Supply Voltage:  
Negative  
-2.75  
Supply Current:  
Positive  
mA  
mA  
Supply Current:  
Negative  
ISS  
-3.5  
-4.5  
Analog Inputs  
Current Sensor Inputs  
(Differential)  
Input Current Range  
IRIIP, IRIIN  
-25  
-4  
25  
4
μA  
Peak value  
With R = 4.7kconnected  
to AGND  
Offset Voltage  
VOIIP, VOIIN  
mV  
Voltage Sensor Inputs  
(Asymmetrical)  
Input Current Range  
IRIVP  
-25  
-4  
25  
4
μA  
Peak value  
With R = 4.7kconnected  
to AGND  
Offset Voltage  
VOIVP  
mV  
Digital Outputs  
At rated input conditions:  
14µARMS on voltage  
channel, 16μARMS on  
current channel  
FOUT Output Frequency  
FMAX  
1.04  
1.16  
1.25  
kHz  
FOUT, DIR, FMO  
Output High Voltage  
Output Low Voltage  
VOH  
VOL  
VDD-1  
V
V
ISOURCE = 5mA  
ISINK = 5mA  
VSS+1  
On-chip Voltage Reference  
Reference Voltage  
VR  
-IR  
1.15  
24.4  
1.20  
25.5  
10  
1.25  
26.6  
70  
V
μA  
With R = 47kconnected  
to VSS  
Reference Current  
Temperature Coefficient  
On-chip Oscillator  
TCR  
ppm/ºC  
Oscillator Frequency  
Temperature Coefficient  
fOSC  
3.15  
3.57  
70  
4.00  
200  
MHz  
TCOSC  
ppm/ºC  
ATTENTION:  
Electrostatic  
sensitive device.  
Requires special  
handling.  
During manufacturing, testing and shipment we take great care to protect our products against potential external  
environmental damage such as Electrostatic Discharge (ESD). Although our products have ESD protection circuitry,  
permanent damage may occur on products subjected to high-energy electrostatic discharges accumulated on the  
human body and/or test equipment that can discharge without detection. Therefore, proper ESD precautions are  
recommended to avoid performance degradation or loss of functionality during product handling.  
SPEC-3094 (REV. 2)  
29-09-2017  
2/14