SA4106A  
PIN DESCRIPTION  
Designation  
Pin No.  
Description  
Analog Ground. This is the reference pin for the current and voltage signal sensing  
AGND  
20  
networks. The supply voltage to this pin should be mid-way between VDD and VSS  
.
Positive Supply Voltage. The voltage to this pin should be +2.5V ± 10% with respect to  
AGND.  
VDD  
VSS  
8
Negative Supply Voltage. The voltage to this pin should be -2.5V ± 10% with respect to  
AGND.  
14  
Analog Input for Voltage. The maximum current into the voltage sense input IVP should be  
set at 16µARMS. The voltage sense input saturates at an input current of ±25µA peak.  
IVP  
19  
2, 1  
Analog Inputs for Current. The maximum current into the current sense inputs IIP/IIN should  
be set at 16µARMS. The current sense inputs saturate at an input current of ±25µA peak.  
IIP, IIN  
This pin provides the connection for the reference current setting resistor. A 47kresistor  
connected to VSS sets the optimum operating conditions.  
VREF  
3
Rated Condition Select inputs. These input pins are used for selecting between the different  
rated condition configurations. Refer to the Rated Condition Select section.  
R0, R1, R2, R3  
6, 5, 4, 11  
Fast Mode Select input. This three state input is used to select between STANDARD and  
FAST mode and provides an extended selection of meter constants. Refer to the Rated  
Condition Select and Fast Mode Select sections.  
FMS  
DIRI  
7
18  
9
Direction Select input. This input is used to enable either bidirectional or unidirectional  
energy measurement.  
Anti-Creep Threshold Select input. This three state input is used to select the anti-creep  
threshold. It is also used to deactivate the anti-creep feature. Refer to the Anti-Creep  
Threshold Select section.  
ACSEL  
Anti-Creep State output. This output pin indicates the state of the anti-creep circuit. Refer  
to the Anti-Creep State Output section.  
ACST  
DIRO  
LED  
16  
17  
13  
Direction Indicator output. This output indicates the direction of energy flow.  
Calibration LED output. Refer to the Rated Condition Select section for the pulse rate output  
options.  
Motor pulse outputs. These outputs can drive an electro-mechanical counter directly. Refer  
to the Rated Condition Select section for the pulse rate output options.  
MON, MOP  
NC  
15, 12  
10  
No connection, leave unconnected.  
1
2
20  
19  
18  
17  
16  
15  
14  
13  
12  
11  
IIN  
IIP  
AGND  
IVP  
ORDERING INFORMATION  
Part Number  
Package  
3
VREF  
R2  
DIRI  
DIRO  
ACST  
MON  
VSS  
LED  
SA4106ASAR  
SOIC20 (RoHS compliant)  
4
5
R1  
6
R0  
7
FMS  
VDD  
ACSEL  
NC  
8
9
MOP  
R3  
10  
Figure 3: Pin connections  
SPEC-1587 (REV. 5)  
29-09-2017  
4/18