SA4104A / SA4104B  
The Rated Condition Select pins (R0, R1, R2, R3) together  
with the FMS pin are used to select different LED output  
frequencies which in turn determine the applications meter  
constant. Refer to Figure 9 for the LED output timing diagram.  
When the FAST mode is enabled the LED output generates  
pulses at a nominal frequency of 5kHz at IMAX and VMAX. In  
this mode the pulse frequency is proportional to the average  
power consumption measured. This mode is useful when  
interfacing to a microcontroller.  
Table 3 illustrates some of the possible LED and motor  
constants that are achievable for some common values of  
IMAX using a VNOM between 220V and 240V.  
Table 2: LED and motor division factors  
FMS  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
R3  
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
R2  
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
R1  
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
R0  
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
DF_LED DF_MO  
220  
440  
880  
1760  
220  
440  
880  
1760  
220  
440  
880  
1760  
220  
440  
880  
1760  
1464  
2928  
352  
704  
584  
1168  
352  
704  
584  
1168  
352  
704  
292  
584  
234  
468  
256  
128  
64  
32  
128  
64  
32  
16  
64  
32  
16  
8
When FMS is floating the LED pin outputs fast mode pulses.  
The motor pulses occur as usual based on the last FMS  
before a floating condition was detected as well as the current  
states of R0, R1, R2 and R3. If a floating condition on FMS is  
detected at device start-up the motor pulses are generated  
based on FMS set to VSS  
.
Rated Condition Select (R0, R1, R2, R3)  
The Rated Condition Select inputs (R0, R1, R2 and R3) along  
with the Fast Mode Select input (FMS) are used for obtaining  
a multitude of meter constants and motor drive ratios. The  
different LED and motor division factors (DF_LED and  
DF_MO) that can be selected via R0, R1, R2, R3 and FMS  
are shown Table 2.  
32  
16  
8
4
To calculate the LED output pulse constant in STANDARD  
mode and the motor drive pulse constant for any meter rating  
(IMAX and VNOM) the following formulae can be used:  
64  
32  
64  
32  
32  
16  
32  
16  
16  
8
퐼푉푃 5000 1000 × 3600  
퐿퐸퐷 ꢀ푚푝/푘푊ℎ =  
×
×
16 퐷ꢉꢊꢋ ꢌ푂푀 × 퐼푀퐴푋  
...(1)  
where  
IMAX is the maximum rated mains current,  
VNOM is the nominal mains voltage,  
IVP is the analog input current on the voltage sense input at  
VNOM as specified in Table 1 and  
DF_LED is the dividing factor for the LED output that is set by  
the combination of R0, R1, R2, R3 and FMS as specified in  
Table 2.  
16  
8
16  
8
Equation 1 is based on the assumption that the input current  
into the IIP/IIN current sense input is set to 16μARMS at IMAX  
.
16  
8
퐿퐸퐷 ꢀ푚푝/푘푊ℎ  
ꢇ표푡표푟 ꢀ푚푝/푘푊ℎ =  
퐷퐹_ꢇꢍ  
1
Note:  
Pin values defined as follows  
(2)  
0
1
pin is connected to VSS  
pin is connected to VDD  
where  
LED imp/kWh is the LED constant as calculated using  
Equation 1 and  
DF_MO is the dividing factor for the motor output that is set  
by the combination of R0, R1, R2, R3 and FMS as specified  
in Table 2.  
SPEC-1654 (REV. 4)  
29-09-2017  
10/18