SA2007P  
ssaammeess  
PIN DESCRIPTION  
Designation  
PIN  
Description  
Analog Ground. The voltage to this pin should be mid-way between V and V .  
SS  
20  
GND  
DD  
Positive supply voltage. The voltage to this pin is typically +2.5V if a shunt resistor is used for  
current sensing or in the case of a current transformer a +5V supply can be applied.  
V
DD  
8
Negative supply voltage. The voltage to this pin is typically -2.5V if a shunt resistor is used for  
current sensing or in the case of a current transformer a 0V supply can be applied.  
V
SS  
14  
The current into the A/D converter should be set at 14µA at nominal mains voltage. The voltage  
RMS  
19  
IVP  
sense input saturates at an input current of ±25µA peak.  
Inputs for current sensor - channel 1 and channel 2. The shunt resistor voltage from each channel  
1, 2,  
3, 4  
IIN1, IIP1  
IIN2, IIP2  
is converted to a current of 16µA at rated conditions. The current sense input saturates at an  
RMS  
input current of ±25µA peak.  
This pin provides the connection for the reference current setting resistor. A 24kW resistor  
5
VREF  
connected to V sets the optimum operating condition.  
SS  
Serial clock output. This output is used to strobe data from the external EEPROM.  
6
7
SCL  
SDA  
Serial data. Send and receive data from an external EEPROM.  
9, 12  
MON, MOP  
Motor pulse outputs. These outputs can be used to drive an impulse counter or stepper motor directly.  
Calibration LED output. Refer to section Led Output (LED) for the pulse rate output options.  
Configuration reload input. A falling edge will trigger a register reload from the external EEPROM.  
Current channel select output. This output indicates which channel is been used for kWh metering.  
13  
LED  
15  
RLOAD  
16  
SEL1  
17  
18  
ELT  
Earth loop tamper output. This output indicates an earth loop tamper condition.  
DIRO  
Direction output. This output indicates the energy flow direction  
10, 11  
Test input. Connect to V for normal operation.  
SS  
TEST, TCLK  
ORDERING INFORMATION  
IIN1  
IIP1  
1
2
20 GND  
Part Number  
SA2007PPA  
SA2007PSA  
Package  
DIP-20  
IVP  
19  
IIN2  
IIP2  
3
18 DIRO  
SOIC-20  
ELT  
17  
4
VREF  
SCL  
SEL1  
5
16  
15  
14  
13  
12  
11  
RLOAD  
6
SDA  
VDD  
VSS  
LED  
7
8
MOP  
TCLK  
MON  
TEST  
9
10  
DR-01595  
Figure 2: Pin connections: Package: DIP-20, SOIC-20  