SA2005P  
ssaammeess  
PARAMETER DESCRIPTION  
LED Pulse-Rate (Cled)  
Refer to the EEPROM memory allocation map as well as the  
Signal flow diagram figure 7, for a description of the registers  
used in this section.  
Two bits of byte D22 allow for the selection of 4 different LED-  
Pulse-rates. The LED pulse-width is 10ms. In fast pulse mode,  
the pulse-width is set to 71µs.  
D22[1]  
D22[0] Calibration LED - Output  
Rated Condition (Kr)  
Kr is used to program the rated condition of the meter. Rated  
conditions from less than 10A to several 100A are possible.  
The rated conditions divider as well as the pre-divider is used  
to compensate for individual phase calibration. The three  
phases are calibrated to the phase with the lowest gain.  
0
1
1
0
1
0
1
0
6400 p/kWh  
3200 p/kWh  
1600 p/kWh  
1252 pulses/second @ rated for  
fast calibration  
Kr is calculated as follows:  
Counter Resolution (Cres)  
Krx=642 000/Rated volt/Rated current/6400x3600x1000/512  
A 13 bit divider divide the pulse rate from the rated conditions  
divider down to the desired counter resolution.  
The SA2005P’s internal counters count from 0 so 1 must be  
subtracted from Kr:  
Cres is made up of bits 0 of 4 of byte D26 and byte D27.  
Kr = round(Krx)-1  
D26[4:0] D27[7:0] Counter Resolution  
Where:  
Counter Pulse-Width (Pw)  
Krx is the real value  
Kr is the integer value  
Kr is made up of 1 byte (D20)  
The pulse width for the mechanical counter driver output is  
selectable to accommodate various step-motor and impulse-  
counter requirements.  
Pre-divider (Cb1, Cb2, Cb3)  
Pw is made up of bits 7 and 6 of byte D26.  
The channel balance (Cb) value is used to balance the three  
phases. The rated conditions divider ratio must be calculated.  
Error measurements per phase are done with channel balance  
values set to zero. The measured error values are used to  
correct the error measurements of the three phases. The  
rounding error in the rated conditions divider is also  
compensated for in the channel balance calculations. One  
count on the channel balance value represent 100%/256.  
Gain = ((Krx-Kr+1) / Krx) x 100  
D26[7]  
D26[6] Counter Pulse-Width  
1
0
0
-
284 ms  
142 ms  
71 ms  
1
0
Creep current threshold (Ct)  
The creep current is expressed relative to the rated current of  
the meter. The SA2005P will not meter currents below the  
creep current. The creep current is implemented to prevent  
the meter from accumulating energy when no load is  
connected.  
Gain calculates the rounding error made by the rated  
conditions divider.  
Cb1 = (CHB1 - CBMIN + Gain) x 256 / 100  
Cb2 = (CHB2 - CBMIN + Gain) x 256 / 100  
Cb3 = (CHB3 - CBMIN + Gain) x 256 / 100  
Cs is made up of bit 7 of byte D16  
D16[7]  
Creep threshold  
CHB1, CHB2, CHB3 is the measured channel balance %error  
that will be corrected  
0
1
0.02% of rated current  
0.01% of rated current  
CBMIN is the lowest channel balance %error measured  
between the three phases.  