SA2002P  
sames  
creep threshold. The creep threshold is implemented to  
prevent the meter from accumulating energy when no load is  
connected.  
be programmed. During the Kr calculation the value was  
rounded up and any rounding error is now taken into account. A  
ratio of the rounding "error" is calculated relative to the center  
of the variable range of Cor (481 - 512).  
Corr = 495 x (1 + (Krx - (Kr + 1)) / Krx)  
Corr = 495 x (1 + (39.61549 - 40) / 39.61549)  
Corr = 495 x 0.990294  
Cs is made up of bit 0 of byte D14.  
D14[0]  
Creep threshold  
0
1
0.02% of rated current  
0.01% of rated current  
Corr = 490.1955  
Corr = 490 (Convert to Integer)  
Cor = Corr -1  
Cor = 489  
Metering direction select (Ds)  
The SA2002P may be configured to measure positive energy  
or positive and negative energy.  
Store the calculated values in the EEPROM  
Ensure that the device reload its registers from the EEPROM  
by means of the RLOAD pin or power down the meter and  
power up again.  
Ds is made up of bit 2 of byte D14.  
D14[2]  
Metering direction select  
0
1
Bi-directional energy measurement  
Positive energy measurement  
The meter is now set up with the correct register values but not  
yet calibrated.  
DC or AC measurement mode (Dc)  
The following example shows how to calibrate the meter  
The SA2002P may be configured to measure AC energy or DC  
energy. In case of AC measurement selection, the device will  
track the mains frequency for offset cancellation purposes. In  
DC measurement mode the device is locked to a fixed  
frequency for offset cancellation. The FMO output is switched  
to 28Hz in DC mode.  
Measure the %Error with a Watt hour standard  
%Error =(Measured Energy - Real Energy)/Real Energy x 100  
The %Error will be worked back into the calculations above.  
For this example we will assume a 2.83% error between the  
correct energy value and energy measured by the SA2002P.  
Dc is made up of bit 3 of byte D14.  
D14[3]  
Recalculate the Kr value  
DC or AC measurement mode  
AC measurement mode  
Krx = 641454 / Unom / Imax / M x 3600 x 1000 / 495 x (1 +  
0
1
%Error / 100 )  
DC measurement mode  
Krx = 641454 / 230 / 80 / 6400 x 3600 x 1000 / 495 x 1.0283  
Krx = 40.73661  
Example of calculating Kr and Cor values  
Krx = 41 (Round up and make integer value)  
Metering specifications:  
Kr = Krx-1  
Unom  
=
=
=
230V  
Kr = 41-1  
Imax  
80A  
Kr = 40  
Meter constant  
6400 p/kWh  
The value 40 is stored in the Kr.  
Calculate the Kr value:  
The Cor value must be recalculated.  
Corr = 495 x (1 + (Krx - (Kr + 1)) / Krx)  
Corr = 495 x (1 + (40.7366 - 41) / 40.7366  
Corr = 495 x 0.993534  
Krx = 641454 / Unom / Imax / M x 3600x1000/495  
Krx = 641454 / 230 / 80 / 6400 x 3600 x 1000 / 495  
Krx = 39.61549  
Krx = 40 (round Krx up to convert to integer)  
Kr = Krx-1  
Corr = 491.7995  
Corr = 492 (Convert to Integer)  
Cor = Corr-1  
Kr = 39  
Cor = 491  
The value 39 is stored in the Kr register. The pre-divider (Cor)  
value is calculated next. Cor is programmable to divide  
between 481 and 512. Only the 5 least significant bits need to  
Store the calculated values in the EEPROM and the meter is  
calibrated.  
9/14  
http://www.sames.co.za