PM9604/5AP
6. Jumper Configurations
The jumper configufations required for the two devices types are shown below:
JUMPER POSITION
JP1 1 - 2
JP2 1 - 2
JP3 1 - 2
JP4 1 - 2
2 - 3
SA9604A
Insert
SA9605A
Insert
NOTES
Insert
Insert
Note 1
Insert
Insert
Remove
Remove
Insert (SCK)
Remove
Insert (CS)
Remove
Insert (DI)
Remove
Insert (FOUT1)
Insert (FOUT2)
Remove
Note 2
Note 3
Note 3
3 - 4
JP5 1 - 2
2 - 3
Insert (PGM1=1)
Remove (PGM1=0)
Insert (PGM0=1)
Remove (PGM0=0)
Insert
JP6 1 - 2
2 - 3
JP7 1 - 2
Note 1:
Note 2:
The removal of the link on the current sensor input must only be
performed during calibration.
Only one of the two output pulse signals on the SA9605A may be
selected at any one time using this module. In a users application both
of these signals may be used.
Note 3:
The SA9605A I.C. has on-board pull-down resistors, pull-up connection
to VDD is, therefore, the only connection which must be catered for.
5/14