Primary lithium battery
LS 33600
3.6 V Primary lithium-thionyl chloride (Li-SOCl
2
)
High energy
D-size bobbin cell
Benefits
l
l
l
l
High voltage response, stable
during most of the lifetime of the
application
Wide operating temperature
range
(- 60°C/85°C)
Easy integration in compact
system
Low self-discharge rate
(less than 1 % after 1 year of
storage at + 20°C)
Cell size references
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity
(at 5 mA + 20°C 2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
Open circuit voltage
Nominal voltage
Nominal energy
(at + 20°C)
(at 0.7 mA + 20°C)
D
17.0 Ah
3.67 V
3.6 V
61.2 Wh
Key features
l
l
l
l
l
l
l
l
Stainless steel container
Hermetic glass-to-metal sealing
Built-in safety vent
Finish with or without flat
positive end
Non-flammable electrolyte
Compliant with IEC 60086-4
safety standard and
IEC 60079-11 intrinsic safety
standard
Underwriters Laboratories
(UL)
Component Recognition
(File Number MH 12609)
Restricted for transport
(Class 9)
Pulse capability: Typically up to 400 mA
(400 mA/0.1 second pulses, drained every 2 mn at + 20°C from undischarged cells with 10 µA
base current, yield voltage readings above 3.0 V. The readings may vary according to the pulse
characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
Storage
(recommended)
(for more severe conditions, consult Saft)
250 mA
+ 30°C (+ 86°F) max
- 60°C/+ 85°C
(- 76°F/+ 185°F)
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult Saft)
Physical characteristics
Diameter (max)
Height (max)
33.4 mm (1.32 in)
60.2 or 61.6 mm
(2.37 in or 2.42 in)
depending on finish type
90 g (3.2 oz)
approx. 4.5 g
radial tabs
axial leads
flying leads...
etc.
Main applications
l
l
l
l
l
l
l
Utility metering
Automatic meter readers
Buoys
Measuring equipment
Industrial applications
Professional electronics
Marine equipment
Typical weight
Li metal content
Available termination suffix
CN, CNR
CNA (AX)
FL
Optional upon request
l
Low magnetic version
July 2010