Voltage plateau versus Current and Temperature (at mid-discharge)
LS 14500
3.8
3.6
3.4
+70ºC
+55ºC
3.2
3.0
2.8
2.6
2.4
2.2
+20ºC
Ø 4.2 min
5.5 max
(flat area)
-20ºC
-40ºC
1
0.1
100
10
1000
10000
1000
Current (mA)
1.35 0.3
Typical discharge profiles at + 20°C
Ø 14.44
50 0.3
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
0.11
0.4 0.1
Ø 7.5 0.1
Dimensions in mm.
2.2
2.0
1
0.1
100
10
1000
Time (hours)
Storage
Restored Capacity versus Current and Temperature (2.0 V cut-off)
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
l The storage area should be
clean, cool (preferably not
exceeding +30°C), dry and
ventilated.
Warning
l Fire, explosion and burn hazard.
l Do not recharge, short circuit,
crush, disassemble, heat above
°
°
100 C (212 F), incinerate,
or expose contents to water.
l Do not solder directly to the cell
(use tabbed cell versions instead).
0.01
0.1
1
10
100
Current (mA)
Doc. No 31064-2-0909
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
Saft
Specialty Battery Group
12, rue Sadi Carnot
For more details on primary lithium technologies please refer to
Primary Lithium Batteries Selector Guide Doc No 31048-2.
93170 Bagnolet - France
Tel.:+33 (0)1 49 93 19 18
Fax:+33 (0)1 49 93 19 69
Published by the Communications Department.
Photo credit: Saft
Société anonyme au capital de 31 944 000
RCS Bobigny B 383 703 873
www.saftbatteries.com
Produced by Arthur Associates Limited.