Primary lithium battery
LS 14500Ex
3.6 V Primary lithium-thionyl chloride (Li-SOCl
2
)
High energy density
AA-size bobbin cell
For demanding and potentially explosive atmospheres
Benefits
l
l
l
l
l
Used in potentially explosive
atmospheres
Enhanced capacity
High voltage response, stable
during most of the lifetime of
the application
Wide operating temperature
range
(- 60
°C/+
85
°C)
Low self-discharge rate
(less than 1 % after 1 year of
storage at + 20
°C)
Non-flammable electrolyte
Compliant with IEC 60079-11
intrinsic safety standard and
IEC 60086-4 safety standard
Stainless steel container and
end caps
(low magnetic signature)
Hermetic glass-to-metal sealing
Underwriters Laboratories
(UL)
Component Recognition
Non-restricted for transport
Manufactured in UK and China
Gas metering
Automatic meter reading
Alarms and security devices
Miners cap lamps
Gas detectors
Air monitoring equipment
Safety torches
Gas tanks level monitoring
Miner equipment
Cell size references
Electrical characteristics
(
typical values relative to cells stored for one year or less at + 30
°C
max.)
Nominal capacity
(at 2 mA + 20
°C
2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
Open circuit voltage
Nominal voltage
Nominal energy
(at + 20°C)
(at 0.2 mA + 20°C)
R6 - AA
2.6 Ah
3.67 V
3.6 V
9.36 Wh
Key features
l
l
Pulse capability: Typically up to 250 mA
(250 mA/0.1 second pulses, drained every 2 mn at +20
°C
from undischarged cells with 10 µA
base current, yield voltage readings above 3.0 V. The readings may vary according to the pulse
characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(Higher currents possible, consult Saft)
Storage
(recommended)
(for more severe conditions, consult Saft)
50 mA
+ 30°C (+ 86°F) max
- 60°C/+ 85°C
(- 76°F/+ 185°F)
l
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult Saft)
l
l
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
CN, CNR
2 PF, 3 PF, 3 PF RP, 4 PF
CNA (AX)
FL
radial tabs
radial pins
axial leads
flying leads...etc.
14.55 mm (0.57 in)
50.3 mm (1.98 in)
16.7 g (~ 0.6 oz)
approx. 0.7 g
l
l
Main applications
l
l
l
l
l
l
l
l
l
IEC 60079-11 Intrinsic safety characteristics
(T4 up to + 55°C)
I
short-circuit current (max)
Ri (max)
Temperature rise (max)
3.7 A
989 mOhm
+ 78°C