LO 35 SX
Voltage plateau versus Current and Temperature
3.0
2.9
2.8
2.7
2.6
2.5
2.4
+ 55ºC
+ 20ºC
+
0ºC
- 20ºC
38 ꢂꢂ
(1.5 ꢃin
- 30ºC
- 40ºC
2.3
2.2
35.2 ꢀ.ꢁ ꢂꢂ
(1.386 ꢀ.ꢀ2ꢁ ꢃin
10
100
1000
10000
Current (mA)
_
25.6 ꢀ.3 ꢂꢂ
(1.ꢀꢀ8 ꢀ.ꢀ12 ꢃin
Typical discharge profiles at + 20ºC
3.0
2.8
2.6
2.4
2.2
2.0
4.8 ꢂꢂ
(ꢀ.19 ꢃin
0.1 A
0.25 A
0.5 A
0.75 A
1 A
Overall dimensions
1.5 A
1.8
0
1
1.5
2
2.5
3
0.5
Handling precautions
Capacity (Ah)
w Cell is pressurised at ambient
temperature.
w Do not puncture, open or mutilate.
w Do not obstruct the safety vent
mechanism.
w Do not short circuit or charge.
w Do not expose to fire or
temperatures above
Restored Capacity versus Current and Temperature (2.0 V cut-off)
3.0
2.75
2.5
2.25
2.0
+ 20ºC
+ 55ºC
1.75
1.5
º
º
+70 C (+158 F).
0ºC
1.25
1.0
- 20ºC
0.75
- 30ºC
- 40ºC
0.5
0.25
0
10
100
1000
10000
Current (mA)
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel.:+33 (0)1 49 93 19 18
Fax:+33 (0)1 49 93 19 69
Doc. N° 31083-2-0908
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
For more details on primary lithium technologies please refer to
Primary Lithium Batteries Selector Guide Doc Nº 31048-2.
313 Crescent Street
Valdese, NC 28690 - USA
Tel.:+1 (828) 874 41 11
Fax:+1 (828) 879 39 81
Published by the Communications Department.
Photo credit: Saft.
Société anonyme au capital de 31 944 000
RCS Bobigny B 383 703 873
www.saftbatteries.com