欢迎访问ic37.com |
会员登录 免费注册
发布采购

SCP-1K2-12 参数 Datasheet PDF下载

SCP-1K2-12图片预览
型号: SCP-1K2-12
PDF下载: 下载PDF文件 查看货源
内容描述: 900 〜 1200W并联型带PFC功能 [900~1200W Parallel Type With PFC Function]
分类和应用: 功率因数校正
文件页数/大小: 2 页 / 151 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号SCP-1K2-12的Datasheet PDF文件第2页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
900~1200W Parallel Type With PFC Function
Features :
AC 180~260VAC input
SCP-1K2
series
PF>0.98@ 230VAC
Protections: Short circuit/ Overload/ Over voltage/ Over temperature
Built in remote sense function
Built-in remote ON-OFF control
Power good signal
With parallel function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
3 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Note. 4
SCP-1K2-05 SCP-1K2-09 SCP-1K2-12 SCP-1K2-15 SCP-1K2-18 SCP-1K2-24 SCP-1K2-36 SCP-1K2-48 SCP-1K2-60
1K2S-P005
5V
200A
0 ~ 200A
1000W
1K2S-P009
9V
133A
0 ~ 133A
1200W
100mVp-p
1K2S-P012
12V
100A
0 ~ 100A
1200W
120mVp-p
1K2S-P015
15V
80A
0 ~ 80A
1200W
150mVp-p
1K2S-P018
18V
66.6A
0 ~ 66.6A
1200W
180mVp-p
1K2S-P024
24V
50A
0 ~ 50A
1200W
240mVp-p
1K2S-P036
36V
33.3A
0 ~ 33.3A
1200W
360mVp-p
1K2S-P048
48V
24A
0 ~ 24A
1152W
480mVp-p
1.0%
0.5%
0.5%
1K2S-P060
60V
20A
0 ~ 20A
1200W
500mVp-p
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
3.0% Typical adjustment by potentiometer
20%~100% adjustment by 1~5VDC external control
1.5%
1.0%
1.0%
1.0%
1.0%
1.0%
VOLTAGE TOLERANCE
Note.3
2.0%
0.5%
1.5%
180 ~ 260VAC
47 ~ 63Hz
>0.98 / 230VAC
80%
10A / 230VAC
60A / 230VAC
3.5mA / 240VAC
105 ~ 140% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% Follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
82%
84%
85%
86%
89%
89%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
500ms, 50ms, 16ms at full load
260 ~ 370VDC see the derating curve
90%
90%
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) class A
EMC
(Note. 5)
Compliance to EN61000-3-2,3
HARMONIC CURRENT
EMS IMMUNITY
POWER GOOD SIGNAL
SPECIAL FUNCTION
OTHERS
COOLING
MTBF
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
Open collector of NPN transistor
DC Voltage Adj., remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
By fan, >20% load or >50 fan on
37.4K hrs min. MIL-HDBK-217F(25
290*120*132mm (L*W*H)
4.5kg; 4pcs /19kg /CARTON
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name: SCP-1K2-SPEC 2006-03-28