Application Note
Derating
The operating case temperature range of the CHB100/150 series is -40˚C to +100˚C. When operating the CHB100/150 series,
proper derating or cooling is needed .
Following is the derating curve of CHB100/150 without heat sink.
Remote ON/OFF Control
The CHB100/150 Series allows the user to switch the module on and off electronically with remote on/off feature. The
CHB100/150 Series are available with "positive logic" or "negative logic" (option).
Logic Table
ON/OFF (2)
Logic State
(Pin 2)
Logic Low -
Power Dissipated vs Ambient Temperature and Air Flow
35
Power Disspated, Pd (Watts)
30
200 ft./min. (1.0 m/s)
25
20
15
10
5
600 ft./min. (3.0 m/s)
0
0
10
20
30
40
50
60
70
80
90
100
700 ft./min. (3.5 m/s)
800 ft./min. (4.0 m/s)
Ambient Temperature, Ta(Deg. C)
TRIM (7)
300 ft./min. ( 1.5 m/s)
400 ft./min. (2.0 m/s)
500 ft./min. (2.5 m/s)
Natural Convection
20 ft./min. (0.1 m/s)
100 ft./min. (0.5 m/s)
-VIN (4)
HIGH SIGNAL HERE
DISABLE OUTPUT
Switch Closed
Logic High -
Switch Open
Module on
Module off
Module off
Module on
External Output Trimming
Output may optionally be externally trimmed
(±10%) with a fixed resistor or an external
trimpot as shown.
TRIM DOWN
TRIM (7)
10K ohms
TRIMPOT
+SENSE (8)
+SENSE (8)
TRIM UP
Forced Convection Power Derating with No Heat Sink
-SENSE (6)
-SENSE (6)
Where:
The power dissipation (Pd):
Pd = Pi - Po = Po (1-
)/
External Output
The thermal resistance are list below:
Chart of Thermal Resistance vs Air Flow:
AIR FLOW RATE
Natural Convection 20ft./min. (0.1m/s)
100 ft./min. (0.5m/s)
200 ft./min. (1.0m/s)
300 ft./min. (1.5m/s)
400 ft./min. (2.0m/s)
500 ft./min. (2.5m/s)
600 ft./min. (3.0m/s)
700 ft./min. (3.5m/s)
800 ft./min. (4.0m/s)
TYPICAL Rca
7.12
˚C
/W
6.21
˚C
/W
5.17
˚C
/W
4.29
˚C
/W
3.64
˚C
/W
2.96
˚C
/W
2.53
˚C
/W
2.37
˚C
/W
2.19
˚C
/W
Output Noise
The output noise is measured with 10µF tantalum capacitor and 1.0µF ceramic capacitor across output.
+Vout (9)
Ceramic
1.0µF
Resistor
Load
Solid Tantalum
10µF
-Vout (5)
To
Scope
The temperature rise (
T ):
T = Pd * Rca
Output Noise Test Circuit schematic
85
All Specifications Typical At Nominal Line, Full Load and 25˚C Unless Otherwise Noted.
86
CHB150
Negative Logic
Positive Logic