LM339, LM239, LM2901, LM2901V, NCV2901, MC3302
MAXIMUM RATINGS
Rating
Symbol
Value
Unit
Power Supply Voltage
V
CC
Vdc
+36 or 18
+30 or 15
LM239/LM339/LM2901, V
MC3302
Input Differential Voltage Range
V
Vdc
Vdc
IDR
36
30
LM239/LM339/LM2901, V
MC3302
Input Common Mode Voltage Range
V
ICMR
−0.3 to V
CC
Output Short Circuit to Ground (Note 1)
I
Continuous
SC
Power Dissipation @ T = 25°C
P
D
A
1.0
8.0
W
mW/°C
Plastic Package
Derate above 25°C
1/R
q
JA
Junction Temperature
T
150
°C
°C
J
Operating Ambient Temperature Range
T
A
−25 to +85
−40 to +85
−40 to +105
−40 to +125
0 to +70
LM239
MC3302
LM2901
LM2901V, NCV2901
LM339
Storage Temperature Range
T
stg
−65 to +150
°C
ESD Protection at any Pin (Note 2)
Human Body Model
V
ESD
V
1500
200
Machine Model
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. The maximum output current may be as high as 20 mA, independent of the magnitude of V . Output short circuits to V can cause excessive
CC
CC
heating and eventual destruction.
2. V rating for NCV/SC devices is: Human Body Model − 2000 V; Machine Model − 200 V.
ESD
V
CC
- Input
Output
+ Input
GND
NOTE: Diagram shown is for 1 comparator.
Figure 1. Circuit Schematic
http://onsemi.com
2