Preliminary
RT9013
Parameter
Symbol
Test Conditions
Min
0
Typ
--
Max
0.6
5.5
1
Units
V
Logic-Low Voltage
Logic-High Voltage
V
IL
EN Threshold
V
I
1.6
--
--
IH
Enable Pin Current
0.1
μA
EN
Power Supply
Rejection Rate
f = 100kHz
PSRR
IOUT = 300mA
--
--
-40
--
dB
V
IN
= (V
+0.5) to 5.5V,
OUT
Line Regulation
ΔV
0.01
0.2
%/V
LINE
I
= 1mA
OUT
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
T
--
--
170
30
--
--
SD
°C
ΔT
SD
Note 1. Stresses listed as the above “Absolute Maximum Ratings” may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the operational
sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may
remain possibility to affect device reliability.
Note 2. Devices are ESD sensitive. Handling precaution recommended.
Note 3. The device is not guaranteed to function outside its operating conditions.
Note 4. θJA is measured in the natural convection at TA = 25°C on a low effective thermal conductivity test board of JEDEC 51-3
thermal measurement standard. The case position of θJC is on the exposed pad for the WDFN-6L 2x2 packages.
Note 5. Quiescent, or ground current, is the difference between input and output currents. It is defined by IQ = IIN - IOUT under no
load condition (IOUT = 0mA). The total current drawn from the supply is the sum of the load current plus the ground pin
current.
Note 6. The dropout voltage is defined as VIN -VOUT, which is measured when VOUT is VOUT(NORMAL) - 100mV.
Note 7. Regulation is measured at constant junction temperature by using a 2ms current pulse. Devices are tested for load
regulation in the load range from 10mA to 500mA.
www.richtek.com
4