RT7253A
Parameter
EN Input Threshold
Voltage
Logic-High
Logic-Low
Symbol
V
IH
V
IL
V
UVLO
ΔV
UVLO
I
SS
t
SS
T
SD
V
SS
= 0V
C
SS
= 0.1μF
V
IN
Rising
Test Conditions
Min
2.7
--
3.8
--
--
--
--
Typ
--
--
4.2
320
6
13.5
150
Max
5.5
0.4
4.5
--
--
--
--
Unit
V
V
mV
μA
ms
°C
Input Under Voltage Lockout Threshold
Input Under Voltage Lockout Hysteresis
Soft-Start Current
Soft-Start Period
Thermal Shutdown
Note 1.
Stresses listed as the above
"Absolute
Maximum Ratings" may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
Note 2.
θ
JA
is measured in natural convection at T
A
= 25°C on a high effective thermal conductivity four -layer test board of
JEDEC 51-7 thermal measurement standard. The measurement case position of
θ
JC
is on the exposed pad of the
package.
Note 3.
Devices are ESD sensitive. Handling precaution is recommended.
Note 4.
The device is not guaranteed to function outside its operating conditions.
DS7253A-02 March 2011
www.richtek.com
5