RT5710D
Parameter
Soft-Start Time
Minimum Off Time
Output Discharge Switch On
Resistance
Symbol
t
SS
Test Conditions
Min
--
--
--
Typ
1.2
120
1.8
Max
--
--
--
Unit
ms
ns
k
Note 1.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These
are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in
the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions may affect
device reliability.
Note 2.
JA
is measured under natural convection (still air) at T
A
= 25C with the component mounted on a high
effective-thermal-conductivity four-layer test board on a JEDEC 51-7 thermal measurement standard.
JC
is measured
at the exposed pad of the package.
Note 3.
Devices are ESD sensitive. Handling precaution recommended.
Note 4.
The device is not guaranteed to function outside its operating conditions.
Copyright © 2019 Richtek Technology Corporation. All rights reserved.
is a registered trademark of Richtek Technology Corporation.
DS5710D-04
November 2019
www.richtek.com
5