Tax Pulse Filter Inductor
Single Inductance
Vary capacitor value for 12 KHz or 16 KHz
Rhombus Part Number:
F-3503
Electrical Specifications at 25
O
C
Materials used in the
construction of this
component meet or
exceed UL Class B and
can be operated up to 130
o
C
Parameter
Min.
Typ.
Max.
Units
Schematic
1
Inductance (Pins 1-3)
D.C. Resistance
Current
"12 KHz" Capacitor
"16 KHz" Capacitor
Single LC attenuation
Dual LC attenuation
1. Tested at 10KHz and 100 mV
RMS
6.19
10.5
6.52
12.05
6.84
13.6
70
mH
Ω
mADC
nF
nF
dB
dB
25.0
14.0
27.0
15.0
25
40
28.0
15.7
3
Table #1
Physical Dimensions in inches (mm)
“Tax Pulse” Frequencies
for various countries:
Country
Frequency
Austria
12 kHz
Belgium
16 kHz
Switzerland
12 kHz
Germany
16 kHz
Denmark
12 kHz
Spain
12 kHz
France
12 kHz
Great Britain
50 Hz*
Greece
16 kHz
Italy
12 kHz
Ireland
12 kHz
Israel
16 kHz
Norway
16 kHz
Netherlands
50 Hz*
Portugal
12 kHz
Sweden
12 kHz
Finland
16 kHz
Turkey
12 kHz
Yugoslavia
16 kHz
Australia
12 kHz
Czechoslovakia 16 kHz
*Common-mode
(longitudinal) signal
.450
(11.43)
MAX.
.025
(0.64)
TYP.
.200
(5.08)
.400
(10.16)
.571
(14.50)
MAX.
1
2
3
.551
(14.00)
MAX.
6
5
4
Specifications subject to change without notice.
For other values & Custom Designs, contact factory.
TAXFILTR - 10/98
Rhombus
Industries Inc.
19
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960
•