RF / IR Encoder / Decoder Chipset  
RF Evaluation Boards,  
RF600D  
Pin Descriptions  
Pin  
Number  
Input /  
Output?  
Name  
Description  
1
2
Out  
Out  
Out  
In  
Data Output 3 (S2)  
Data Output 4 (S3)  
OP3  
OP4  
3
Low Battery, goes Low when Low Battery Valid  
Positive supply voltage connection  
Connect to GND  
LB  
4
Vcc  
5
In  
Vss  
6
Out  
Out  
In / Out  
In  
Connects to EEPROM ‘CS’ pin  
Connects to EEPROM ‘CLK’ pin. Also sets data mark.  
Connects to EEPROM ‘Data’ pin  
RF / IR Data input  
ECS  
7
ECLK  
EDAT  
IN  
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
In  
Learn / Erase Switch Input & Status LED Drive  
Serial Data output  
LRN  
Out  
In  
SD1  
Option Link Input for Momentary or Latched outputs  
High = Run, Low = Sleep Mode  
Positive supply voltage connection  
No Connection  
LKIN  
SLEEP  
Vcc  
In  
In  
N/A  
N/A  
Out  
Out  
Unused  
Unused  
OP1  
No Connection  
Data Output 1 (S0)  
Data Output 2 (S1)  
OP2  
Vcc / Vss  
The power supply needs to be a stable regulated voltage with <10mV ripple  
OP1-4  
Digital Data outputs 1-4. These outputs are asserted LOW when the relevant inputs (S0 – S3) on the  
RF600E are asserted. (see latch/unlatch information under ‘LKIN’).  
LB  
The RF600E automatically measures the battery voltage each time it is operated (see RF600E data). This  
information is transmitted to the RF600D and if a low battery condition exists then the low battery output is  
taken low. This indication is latched until data from a decoder with a good battery is received at which time  
the output indication is cleared. (output goes high).  
ECS / ECLK / EDAT  
These connections are for interface to the EEPROM, which is used to store the identity of the encoders  
taught to the system.  
ECLK AM / FM Selection  
Note that the ECLK output to the EEPROM is also used for data mark selection. The data mark input sets  
the input of the RF600D to be compatible with AM or FM radio modulation.  
When the ECS control line is low (i.e. when the EEPROM is not selected) the ECLK line is made an input  
and a check is made for the presence of a pull-down or pull-up resistor.  
If the data mark selection is pull-down then the RF600D will be set to receive Sync Low AM data.  
If the data mark selection is pull-up then the RF600D will be set to receive Sync High FM and IR data.  
DS600-9 Sept ‘04  
©2004 Reg. No. 227 4001, ENGLAND  