RF600T-EVAL
Smart Radio Evaluation Kit
Option link settings:
The following table provides a list of the option links that are provide on the evaluation board for
setting the parameters of the “Smart Radio” devices. Please note that only either a RF600T or a
TRXQ1 should be fitted at any one point in time. If the evaluation board is to be used with the
RF600T then the user has the option of being able to select from a choice of 3 types of radio
module. The RXQ1 is a complete transceiver radio module while the RTFQ1/RRFQ1 and
RTFQ2/RRFQ1 are individual transmitter and receiver radio modules.
Option link
OPT 1
OPT 2
OPT 3
OPT 4
OPT 5
OPT 6
TXQ1CH
RXQ01-RXQ05
RXQ1CH
RT101-RT104
RF Baud
Host Baud
Description
Link in
200us element time
is selected
19200 Baud Rate
Loop mode enabled
Activate
Activate
Broadcast Mode
434.33MHz
Active
434.33MHz
Active
Link out
400us element time
selected
9600 Baud Rate
Normal operation
Deactivate
Deactivate
Addressed mode
433.92MHz
Inactive
433.92MHz
Inactive
\CTS (loop)
Telemetry IN#1
Telemetry IN#2
Mode
TRXQ1 frequency select
These links allow the use of the
RXQ1 radio module
RXQ1 radio module frequency
select
These links allow the use of the
RTFQ1 and RRFQ1 radio
modules
These links allow the use of the
RTFQ2 and RRFQ2 radio
modules
RT201-RT204
Active
Inactive
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E Sussex, BN8 6JL, England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
Email sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
R F Solutions is a member of the Low Power Radio Association.
All Trademarks acknowledged and remain the property of the respected owners.
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such
information. Use of R.F. Solutions as critical components in life support systems is not authorised except with express written approval from R. F. Solutions Ltd.
DS605-2
25 FEB 2005
th
©2005 Reg. No. 227 4001, ENGLAND