Modular Radio Telemetry System
200 Series
Output Modules
211 Darlington Output
•
•
•
•
16 transistor switch outputs
Switched
Outputs 1-4
Ground
Connections
Switched
Outputs 9-12
Each Output switches to GND when operated
Each output rated 500mA at up to 50Vdc
Total cumulative output of module 1A @50Vdc
210 Rx
211
The only connections required are
Switched
Outputs 13-16
Switched
Outputs 5-8
•
Screw terminals to connect to each channel
output.
•
Direct connection to the 210 Receiver via the four ribbon cables / connectors supplied.
Dimensions: Within DIN Rail: 70 x 82mm (PCB: 64 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Supply Voltage
Operating Temperature: 0 to +55o Celsius.
Min
Typical
Max
Units
From 210Rx module
Output voltage
50
VDC
Continuous current Load:
Per Channel
Total module
500
1,000
mA
mA
‘215’ Relay Output Module
•
•
8 relay switches rated 230Vac at 5A
Each relay provides ‘input’ and ‘normally open’ screw
terminals
Relay Outputs 1 - 4
210 Rx
The only connections required are
•
Connection to the 210 Receiver via the ribbon cable
supplied.
215
•
Connection to each relay via screw terminals provided.
Relay Outputs 5 - 8
Dimensions: Within DIN Rail: 93 x 82 mm (PCB: 90 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Supply Voltage
Operating Temperature: 0 to +55o Celsius.
Min
Typical
Max
Units
From 210Rx module
Relay* output Rating
Type HRS1KH3-12
Max rating is 3A/220VAC/30VDC
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 10