Modular Radio Telemetry System
Technical Specifications
Dimensions:
Within DIN Rail: 200Tx : 112 x 82 mm (PCB: 109 x 72mm)
201Tx
160 x 82 mm (PCB: 145 x 72mm)
Storage Temperature; -10 to +155
o
C
Operating Temperature; -0 to +55
o
Celsius.
Electrical Characteristics
Min
Typical
Supply Voltage: 12V Supply
10
12
Supply Voltage: 24V Supply
21
24
Antenna Output Lead Impedance
50
Minimum input activation time to trigger transmission
5
433MHz / 433NBMHz Version
Supply Current: Quiescent
10
Supply Current: Transmitting Data
150
170
458MHZ Version
Supply Current: Quiescent
10
Supply Current: Transmitting Data
240
250
200 Series
Max
16
30
Units
V
V
Ohms
ms
mA
mA
mA
mA
200
270
200 Transmitter Current Consumption
433MHz / 433NBMHz Version
Supply Current: Quiescent
Supply Current: Transmitting Data
458MHZ Version
Supply Current: Quiescent
Supply Current: Transmitting Data
201 Transmitter Current Consumption
Supply Current: Quiescent
Supply Current: Transmitting - 433MHz NB module
Supply Current: Transmitting - 458MHz module
Min
Typical
10
170
10
250
Typical
60
50
180
Max
Units
mA
mA
mA
mA
Units
nA
mA
mA
150
200
240
Min
270
Max
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E. Sussex, BN8 6JL, England
Tel +44 (0)1273 898 000
Email sales@rfsolutions.co.uk
Fax +44 (0)1273 480 661
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 8