Addressing
Each transmitter and receiver contains an address Switch. This is used to set the identity of the unit. In order
for a receiver to respond to a transmitter, the addressees must match,. This enables the user to set individual
transmitter and receivers to operate or not operate with each other. It also enables multiple systems to operate
within the same vicinity without causing interference.
Each system is supplied ready configured, and does not need to be altered.
However, if you require a different address (e.g. if you have two systems in close proximity or wish to have
several receivers to one transmitter etc);
There are 8 address ‘Switches’ which the transmitter and receiver use to identify themselves.
The Receiver and Transmitter units must have the same Address ‘Switches’ in order to recognise each
others signal.
The following table shows the Circuit board address ‘Switches’ for the transmitter and receiver circuit boards.
Address Number
Transmitter Address ‘SW1’
Receiver Address ‘LK1’
1
A1
1
2
A2
2
3
A3
3
4
A4
4
5
A5
5
6
A6
6
7
A7
7
8
A8
8
Relay Output Connections
Upto 4 relays are provided on the receiver output. The relay output provides a ‘switch’ output which operates
when the transmitter switch is pressed. Each relay has the connections as below.
NC
COM
COM
NO
Relay Connections
When Transmitter NOT Operating
Relay output ‘1’ provides a longer momentary output (approx �½ second) this may be removed by adding Link
6 on the PCB. The outputs are driven from a Microcontroller and can be customised to specific requirements.
Relay Output Configuration
The two option links OPT1, OPT2 (to the left of the antenna connector on the Rx PCB) set the action of the
relay outputs according to the following table. Please note that these can be customised on request.
OPT1
out
in
out
in
OPT 2
out
out
in
in
Relay 4
�½ Sec Momentary
Momentary
Latching
Relay 3
�½ Sec Momentary
Momentary
Latching
Test Mode
Relay 2
�½ Sec Momentary
Momentary
Latching
Relay 1
Momentary
Momentary
Latching
NO
Relay Connections
When Transmitter OPERATING
NC
DS114-8 Oct ‘03
©2002 Reg. No. 227 4001, England
Page 2