‘105’ S
ERIES
R
EMOTE
R
ECEIVER
D
ECODERS
Connections
ANT
POWER LED
LEARN LED
BATT LOW LED
SW1
J7
LEARN
SWITCH
GND
Connector to
Expander
J14
RLY
9
J9
RLY 1
J10
INFRA-RED
HEADER
D8
D7
D10
D9
F1
T1
J4
E
RF RECEIVER / PAGER
MAINS
TRANSFORMER
J3 J2
N L
230Vac
Mains
J5
VR1
CH4
RLY 2
J11
CH2
RLY 3
J12
CH3
0V 12-30
Vdc
CH4
RLY 4
The
decoder
requires
either a
single
12-30 Vdc
supply or
240Vac
mains.
NOT BOTH!
N/O COMM N/C
LOW BATT
N/O COMM N/C
O/P1
N/O COMM N/C
O/P2
N/O COMM N/C
O/P3
N/O COMM N/C
O/P4
Warning!
The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing
the cover ensure that the mains input supply is removed. Any operation of the product that involves removal
of the front cover should only be carried out by a competent person or qualified electrician.
Configuration the Outputs (Jumper Links J2, J3)
These links configure the operation of the digital outputs according to the table below.
NOTE:
The link status is read
only
on power up, after changing the links please to remove and re-apply
power.
The system is supplied with relay(s) type OMRON GL5114P or equivalent.
Note:
The user must ensure that the load connected does not overload the relay!
J2
Open
Open
Connected
Connected
J3
Open
Connected
Open
Connected
RL 1
Latch
Timed
Latch
Timed
RL 2
Latch
Momentary
Latch
Momentary
RL 3
Latch
Momentary
Momentary
Latch
RL 4
Latch
Momentary
Momentary
Latch
Latch:
The relay operates until the next valid transmission is received
Momentary:
The relay operates momentarily, or for as long as the Tx encoder switch is held on.
Removing Timed Output:
Turn the trimmer (VR1) fully Clockwise.
Timed Output (O/P1)
This is a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4
minutes 15 seconds. Turning VR1 anti-clockwise increases the output delay.
A timed output is triggered by a signal from the transmitter, subsequent signals from the transmitter will cancel
the timed output.
DS105-6 April ‘05
©2003 Reg. No. 227 4001, England
Page 2