欢迎访问ic37.com |
会员登录 免费注册
发布采购

10209S1-433F 参数 Datasheet PDF下载

10209S1-433F图片预览
型号: 10209S1-433F
PDF下载: 下载PDF文件 查看货源
内容描述: KEELOQ远程控制系统, 230V交流 [KEELOQ REMOTE CONTROL SYSTEMS, 230Vac]
分类和应用: 远程控制
文件页数/大小: 5 页 / 71 K
品牌: RFSOLUTIONS [ RFSOLUTIONS.LTD ]
 浏览型号10209S1-433F的Datasheet PDF文件第1页浏览型号10209S1-433F的Datasheet PDF文件第2页浏览型号10209S1-433F的Datasheet PDF文件第4页浏览型号10209S1-433F的Datasheet PDF文件第5页  
K
EELOQ
R
EMOTE
C
ONTROL
S
YSTEMS
, 230Vac
Data Outputs
119, 129
10209
Each of the transmitter switches maps directly to the relay outputs. (SW1 to RLY1, SW2 to RLY2)
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and
Normally Closed (NC).
Relay Connections when
Transmitter NOT Operating
The jumper links ( LK1, LK2 ) configure the outputs to be momentary or latching.
LK1
LK2
O/P 1
O/P2
Open
Open
Mom
Mom
Open
Connected
Mom
Latch
Connected
Open
Latch
Mom
Connected
Connected
Latch
Latch
Note :
In momentary mode the relay will operate for as long as the transmitter switch is held on.
Learning a new Transmitter Encoder
To enter and activate the learn mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the receiver unit OFF and then ON again in ~1sec intervals four times finally leaving the unit
powered up.
3. After 5secs until a ‘beep’ sound is heard.
4. The unit is now in ‘learn’ Mode.
5. Briefly press a button on the transmitter, the receiver unit will ‘beep’ twice.
6. Briefly Press the transmitter button again, he receiver unit will ‘beep’ three times.
7. Wait 10sec for the unit to return to ‘normal operation’ mode.
8. The transmitter is now ‘learnt’ to the receiver unit and will operate the output relays.
Erasing Transmitter Encoders form Memory
To enter and activate the erase mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the unit off and then on again in ~1sec intervals six times finally leaving the unit powered up.
3. Wait 5secs until a ‘ticking’ sound is heard for a period of 10secs by the operation and release of one of the
relays.
4. Wait 10secs for the receiver unit to return to ‘normal’ mode
5. The unit has now erased all encoder data.
NC
COM
NO
Relay Connections when
Transmitter OPERATING
NC
COM
NO
Note
During Learn and Erase the relays should not be connected to equipment that will be harmed by rapid
changes of the relay polarisation.
DS119-5
June ‘06
©2006
REG No 277 4001, ENGLAND.
Page 3