RF2436
Absolute Maximum Ratings
Caution! ESD sensitive device.
Parameter
Rating
Unit
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
Supply Voltage
0 to +8.0
V
DC
Control Voltage
-1.0 to +6.0
+30
V
Input RF Power
dBm
°C
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
Operating Ambient Temperature
Storage Temperature
-40 to +85
-40 to +150
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.
°C
Specification
Parameter
Unit
Condition
Min.
Typ.
Max.
T=25 °C, V =3.0V, Freq=900MHz
Overall
DD
Frequency Range
Insertion Loss
Isolation
DC to 2500
1
MHz
dB
2
Transmit or receive mode.
Receive mode; ANT I/O to TX IN crosstalk
Transmit mode; ANT I/O to RXOUT crosstalk
Receive mode.
20
20
22
dB
24
dB
RX OUT VSWR
1.1:1
1.1:1
+27
TX IN VSWR
Transmit mode.
Output P1dB
dBm
dBm
Output IP3
+39
Control Logic
CTRL Logic “Low” Voltage
CTRL Logic “High” Voltage
Power Supply
Voltage
0
V
V
Receive mode.
Transmit mode.
0.7
3
1.5 to 6
5
V
V
Specifications
Operating Limits
Receive mode.
Transmit mode.
Current
10
1
μA
mA
0.5
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
2 of 6
Rev A6 DS080128