R1LP0408C-I Series
DC Characteristics
Parameter
Input leakage current
Output leakage current
Operating current
Average operating current
Symbol Min Typ
|I
LI
|
|I
LO
|
I
CC
I
CC1
Max Unit Test conditions
1
1
µA
µA
mA
mA
Vin = V
SS
to V
CC
CS# = V
IH
or OE# = V
IH
or
WE# = V
IL
or V
I/O
= V
SS
to V
CC
CS# = V
IL
,
Others = V
IH
/ V
IL
, I
I/O
= 0 mA
Min. cycle, duty = 100%,
CS# = V
IL
, Others = V
IH
/V
IL
I
I/O
= 0 mA
Cycle time = 1
µs,
duty = 100%,
I
I/O
= 0 mA, CS#
≤
0.2 V,
V
IH
≥
V
CC
−
0.2 V, V
IL
≤
0.2 V
CS# = V
IH
Vin
≥
0 V, CS#
≥
V
CC
−
0.2 V
1.5*
1
3
8*
1
25
I
CC2
2*
1
5
mA
Standby current
Standby current
−5SI
to +85°C
to +70°C
to +40°C
to +25°C
−7LI
to +85°C
to +70°C
to +40°C
to +25°C
Output low voltage
Output high voltage
I
SB
I
SB1
I
SB1
I
SB1
I
SB1
I
SB1
I
SB1
I
SB1
I
SB1
V
OL
V
OH
V
OH2
0.1*
1
0.5
1.0*
0.8*
1
2
mA
µA
µA
µA
µA
µA
µA
µA
µA
V
V
V
10
8
3
0.8*
1
3
20
16
1.0*
2
10
10
0.4
I
OL
= 2.1 mA
I
OH
=
−1.0
mA
I
OH
=
−0.1
mA
2.4
2.6
Notes: 1. Typical values are at V
CC
= 5.0 V, Ta = +25°C and specified loading, and not guaranteed.
2. Typical values are at V
CC
= 5.0 V, Ta = +40°C and specified loading, and not guaranteed.
Capacitance
(Ta = +25°C, f = 1.0 MHz)
Parameter
Input capacitance
Input/output capacitance
Note:
Symbol
Cin
C
I/O
Min
Typ
Max
8
10
Unit
pF
pF
Test conditions
Vin = 0 V
V
I/O
= 0 V
Note
1
1
1. This parameter is sampled and not 100% tested.