M62301SP/FP
(3) Constant current control
Integrating current I
I
can be obtained based on the reference voltage (1.22 V) by the built-in high-precision
generator and resistance R
I
.
I
I
=
1.22
R
I
(A) .................... (1)
Integration time T
I
can be calculated as follows;
T
I
= (V
IN
+ 0.49)
C
I
I
I
.................. (2)
However, parameters such as built-in comparator offset voltage, analog switch offset, voltage leak current and delay
time are not counted.
I
I
V
REF
13
12
8
1.22 V
R
I
C
I
4.45 V
50 mA
Reset supply voltage
V
RE
0.8 V
t
RESET
output
Output
unsettled
T
DE
T
DE
t
When voltage applied to pin V
RE
becomes less than 4.45 V, the
RESET
output status becomes "L". If voltage
increases over 4.50 V, the
RESET
status becomes "H" within 150
µs.
REJ03D0861-0300 Rev.3.00 Mar 25, 2008
Page 5 of 11